Where gas is on site, diesel stops being a fuel and starts being a logistics problem — tanker deliveries, bulk storage, spill containment, filter changes and a running cost that moves with the oil price. The AEE-G-I series takes the same welded container architecture as the diesel range and runs it on the gas you already have.
The full 40 ft high-cube envelope gives the gas train, radiator and exhaust treatment the volume they need for genuine continuous duty, and it ships as a standard ISO container — no abnormal-load permit, no special trailer, no customs surprises.
Standard configuration. Alternative engines, alternators, voltages and frequencies are configurable per order.
| Item | Value |
|---|---|
| Series | AEE-G-I · natural gas |
| Rated power | 1250 kW (1563 kVA) |
| Application | Super-silent natural-gas power station — continuous duty |
| Engine | Weichai |
| Alternator | Stamford · Leroy-Somer · Mecc Alte · Dingge |
| Engine speed | 1500 / 1800 rpm |
| Rated frequency | 50 / 60 Hz |
| Phases | 3 |
| Three-phase rated voltage | 380–480 V |
| Power factor | 0.8 |
| Frequency droop | ≤ 3 % |
| Frequency recovery time | ≤ 3 s |
| Cooling | Dedicated cooling bay; radiator and fan isolated from the engine compartment |
| Noise level | ≤ 70±1dB(A) @ 7m |
| Control system | Digital |
| Paralleling controller | Paralleling controller — brand specified with your order |
| Internal structure | Dedicated compartments for gas train, engine and cooling |
| Enclosure | Container type, fully welded |
| Dimensions (L × W × H) | 12192 × 2438 × 2896 mm (40 ft high-cube) |
| Set weight | 26000kg |
| Fuel supply | Natural gas supply — no diesel tank; automatic engine-oil make-up tank |
| Protection class | IP44 |
| Ambient range | −10 °C to +50°C (−40 °C with jacket water heater) |
| Altitude | ≤ 2000 m |
| Muffler | Hospital-grade, impedance-composite |
| Standards | ISO 8528-5:2018 · ISO 8528-10:2022 · GB/T 2820.5:2025 · CE |
| Transport | Standard 40 ft high-cube container — customs freight saving 20 % + |
Gas-fed plant with no bulk fuel stored on site: close and lock the door and let it run. All side components sit flush so nothing catches in transit.
Heavy acoustic treatment inside a full-height enclosure and wind-tunnel-inspired muffler technology keep a 1.25MW gas plant within industrial site limits.
Gas train, radiator and engine bay are laid out as separate compartments, so cooling air never fights the exhaust heat and the plant holds its rating in summer.
More than 30 % fewer failures than shaft-driven and conventional structures, thanks to an optimised compartment structure, dual filtration and a simplified cooling drive.
Engineered for around-the-clock base load: five 250 kW sets run in parallel, with capacity redundancy for long-run cycles. Even if one engine fails, the load keeps running. And when terminal load changes, it starts or stops units on its own.
One-touch start/stop on the container panel, panel lighting plus internal service lighting for night work, and control redundancy to cut maintenance time. Remote monitoring enables unattended operation.
Field gas and pipeline tail-ends turned into saleable power instead of flared or throttled pressure.
Base load for island communities and remote grids, paralleled in multiples for redundancy.
Factories, processing plants and industrial parks running on their own generation.
Large paralleled blocks for campus-scale loads where gas is already on the utility grid.
Offshore platforms and oilfield camps with HSE-compliant delivery and salt-fog protection.
In certain specific scenarios, natural-gas generation is the first choice for crypto mining. High cost-performance, stable and continuous operation.
The compact workhorse — six units per 13.7 m trailer.
View specificationThe volume seller for event, construction and utility standby fleets.
View specificationA true 20 ft high-cube diesel power station for continuous-duty sites.
View specificationEvery parameter side by side, plus the shared platform specification and options list.
Compare allThis is a standardised 1250 kW super-silent natural-gas generator set. Tell us the kW, quantity, voltage, gas source and destination port — we reply with drawings, weight, gas consumption figures and a quotation.