Above 1 MW the job stops being temporary power and starts being a power station. The set has to carry base load around the clock, in heat, dust and salt air, with service intervals measured in months rather than hire days — and it still has to arrive on a standard truck.
The AEE-D-Ⅲ station series uses the full 20 ft high-cube envelope to give the engine, radiator and exhaust treatment the volume they need for genuine continuous duty, while shipping two units on a 13 m flatbed and keeping the same control platform as the rest of the range.
Standard configuration. Alternative engines, alternators, voltages and frequencies are configurable per order.
| Item | Value |
|---|---|
| Series | AEE-D-Ⅲ · station |
| Rated power | 1000 – 1200 kW (1250 – 1500 kVA) |
| Application | Super-silent power station — continuous duty |
| Engine | Cummins · Baudouin · Perkins |
| Alternator | Stamford · Leroy-Somer · Mecc Alte · Dingge |
| Engine speed | 1500 / 1800 rpm |
| Rated frequency | 50 / 60 Hz |
| Phases | 3 |
| Three-phase rated voltage | 380–480 V |
| Power factor | 0.8 |
| Frequency droop | ≤ 3 % |
| Frequency recovery time | ≤ 3 s |
| Cooling | Forced-air ventilation; radiator and fan in an isolated bay |
| Engine fuel consumption | ≤ 197 g/kWh |
| Noise level | ≤ 65 ±1dB(A) @ 7m |
| Control system | Digital |
| Paralleling controller | SmartGen HGM9510N (ComAp, DSE, DEIF optional) |
| Internal structure | Three independent compartments |
| Enclosure | Container type, fully welded |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm (20 ft high-cube) |
| Set weight | 16000 – 17000 kg |
| Fuel tank | Integrated base tank, 2000 L |
| Protection class | IP44 (IP54 optional) |
| Ambient range | −15 °C to +50°C (−40 °C with jacket water heater) |
| Altitude | ≤ 2000 m |
| Muffler | Hospital-grade, impedance-composite |
| Standards | ISO 8528-5:2018 · ISO 8528-10:2022 · GB/T 2820.5:2025 · CE |
| Transport | 2 units per 13 m flatbed — freight saving 30 % + |
The solid-state battery concept: fill diesel, close and lock the door, walk away. The set runs unattended with high reliability, and all side components sit flush so nothing catches in transit.
Heavy acoustic treatment and wind-tunnel-derived muffler geometry in a full-height enclosure. Keeps a 1 MW+ plant inside industrial and semi-urban site limits.
Three independent compartments, 3 % + better fuel economy and 12 dB + lower noise than the previous generation of canopy designs.
More than 50 % fewer failures than shaft-driven and conventional designs, thanks to a simplified cooling drive path and dual fuel filtration.
Engineered for around-the-clock base load: integrated base tank with level display, optional auto-refuelling, and service access designed for long intervals.
Single-button start/stop on the container panel, panel lighting plus internal service lighting for night work, and control redundancy to cut maintenance time.
Base load for island communities and remote grids, paralleled in multiples for redundancy.
Continuous power at altitude and in dust, with the three-proof package.
Factories, processing plants and industrial parks running on their own generation.
Large paralleled blocks for campus-scale loads.
Offshore platforms and oilfield camps with HSE-compliant delivery and salt-fog protection.
Restoring supply to hospitals, water systems and shelters after grid failure.
The compact workhorse — six units per 13.7 m trailer.
View specificationThe volume seller for event, construction and utility standby fleets.
View specificationA 40 ft high-cube natural-gas plant for base load where gas is already on site.
View specificationEvery parameter side by side, plus the shared platform specification and options list.
Compare allTell us the kW, quantity, voltage, engine preference and destination port — we reply with drawings, weight, fuel curves and a quotation.